Engine will
not
crank/start.
Engine
runs
rough.
Unit does
not move
with engine
running
when using
steering
levers.
1,
1,
Safety interlock
system is not
engaged or is
faulty.
Fuel tanks empty.
2,
3.
Discharged
battery.
4.
Poor connection
between battery
and battery cables.
5.
Spark plug wire(s)
loose or spark
plug(s) faulty.
6.
Faulty electrical
system.
7.
Faulty engine.
1.
Choke engaged.
2.
Air filter cartridge
plugged.
3.
Faulty engine.
1.
The transmission
bypass lever is
engaged.
2.
Faulty hydrostatic
belt.
Faulty
transmission.
2,
3.
4.
Check safety interlock system (see
Safety Interlock System on page 12).
Fill fuel tanks (see FILLING FUEL TANKS
on page 13).
Charge battery (see Charging the Battery
on page 20).
Tighten battery cables and/or clean
battery and battery cables (see Cleaning
Battery and Battery Cables on page 20).
Connect spark plug wire(s) or replace
spark plug(s). Refer to Engine Manual for
detailed instructions.
6.
Contact yourAriens
Dealer.
7.
Contact your Ariens Dealer.
1.
Disengage choke.
2.
Clean or replace air filter cartridge. Refer
to Engine Manual for detailed
instructions.
3.
Contact your Ariens Dealer.
1.
Disengage transmission
bypass lever
(see on page 15).
2,
Replace hydrostatic belt (see
REPLACING
HYDROSTATIC
BELT on
page 22).
3.
Contact your Ariens Dealer.