Changing The Floating-Point Byte Order; Changing The Additional Communications Response Delay; Configuring Variable Mapping - Emerson MICRO MOTION 1500 Configuration And User Manual

Transmitters with the filling and dosing application
Hide thumbs Also See for MICRO MOTION 1500:
Table of Contents

Advertisement

Optional Transmitter Configuration
6.12.4

Changing the floating-point byte order

Four bytes are used to transmit floating-point values. For contents of bytes, see Table 6-7.
Table 6-7
Byte contents in Modbus commands and responses
Byte
Bits
1
S E E E E E E E
2
E M M M M M M M
3
M M M M M M M M
4
M M M M M M M M
The default byte order for the transmitter is 3–4–1–2. You may need to reset byte order to match the
byte order used by a remote host or PLC. Byte order codes are listed in Table 6-8.
Table 6-8
Byte order codes and byte orders
Byte order code
0
1
2
3
6.12.5

Changing the additional communications response delay

Some hosts or PLCs operate at slower speeds than the transmitter. In order to synchronize
communication with these devices, you can configure an additional time delay to be added to each
response the transmitter sends to the remote host.
The basic unit of delay is in terms of 2/3 of one character time as calculated for the current serial port
baud rate setting and character transmission parameters. This basic delay unit is multiplied by the
configured value to arrive at the total additional time delay. You can specify a value in the range 1 to
255.
6.13

Configuring variable mapping

The Variable Mapping panel in the Configuration window provides another way to assign the primary
variable (PV). The PV parameter shown on this panel is the same as the Primary Variable parameter
in the Analog Output panel (see Section 4.5): if you change the parameter here, it is automatically
changed in the Analog Output panel, and vice versa.
The secondary variable (SV), tertiary variable (TV), and quaternary variable (QV) are not used by the
Model 1500 transmitter with the filling and dosing application, and cannot be changed.
Configuration and Use Manual
Definitions
S = Sign
E = Exponent
E = Exponent
M = Mantissa
M = Mantissa
M = Mantissa
Byte order
1
2
3
4
3
4
1
2
2
1
4
3
4
3
2
1
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents