Thermostat with humidity control digital 7-day programmable

Advertisement

Humidifier Control
and Monitoring
When the humidity button is pressed
while in the run mode and in the HEAT
position, the actual humidity will be
displayed on the left side of the
display. HUMD is displayed above
the actual humidity. The humidity set

FAQs

1. My thermostat is reading
Celsius. How do I change it
to Fahrenheit?
2. How do I bypass (not
use) the program?
point is displayed on the right side of
the display.
may be pressed to modify the humidity
set point (range 5 to 50). Maximum
displayed humidity is 97% RH and
minimum displayed humidity is 2%
RH. If the heating system is operating
and there is a demand for humidity,
1F95-391
Press TIME
and TIME
FWD
TIME
until you get to °C then press the
FWD
PROGRAM
to return to normal operation.
RUN
Press PROGRAM
RUN
to bypass the program and operate the thermostat manually press the MODE
to select Heat or Cool (whichever you prefer) and press
TEMP
buttons to set the thermostat on the temperature you want. The temperature
setting you choose will be held until you manually change it using the TEMP
TEMP
buttons. The thermostat will remain in the HOLD mode when you change
temperature and maintain whatever temperature you set. If you decide to return to the
program, press PROGRAM
or
button
at the same time to enter the configuration menu. Press
BACK
to make certain the thermostat is in the run program mode, then
to cancel the hold feature.
RUN
26
then the humidifier will operate. If the
demand for humidity is not satisfied
for ten consecutive heat cycle
operations, the display will show the
word HUMD for one second and the
word MX for one second signaling
maximum possible humidity is
reached.
or
arrow to select °F, press
SYSTEM
. Use the TEMP
HOLD
button
or
or