4. Thread a U.L. approved 30 Amp power cord. NEMA 14-30 type ST or SRDT
through the strain relief.
5. Attach the green power cord ground wire to the cabinet with green ground
screw.
Attach the white (neutral) power cord conductors and the green ground wire
6.
from the dryer harness to the brass-colored center terminal on the terminal
block. Tighten the screw securely.
7. Attach the red and black power cord conductors to the outer brass-colored
terminals on the terminal block.
Warning: Do not make a sharp bend or crimp the wiring /conductor at
connections.
8. Tighten the screws securing the cord restraint firmly against the power cord.
9. Tighten the strain relief nut securely so that the strain relief does not turn.
10. Reinstall the terminal block cover.