What To Do If; Defrosting Of The Freezer - Electrolux ENA34835W User Manual

Hide thumbs Also See for ENA34835W:
Table of Contents

Advertisement

WHAT TO DO IF...

Caution! Before troubleshooting,
disconnect the power supply.
Only a qualified electrician or compe-
tent person must do the troubleshoot-
ing that is not in this manual.
Problem
The appliance is noisy.
The compressor oper-
ates continually.
Water flows on the rear
plate of the refrigerator.
Water flows into the re-
frigerator.
Possible cause
The appliance is not supported
properly.
The Temperature regulator may
be set incorrectly.
The door is not closed correctly.
The door has been opened too
frequently.
The product temperature is too
high.
The room temperature is too
high.
The Action Freeze function is
switched on.
During the automatic defrosting
process, frost defrosts on the
rear plate.
The water outlet is clogged.
Products prevent that water
flows into the water collector.

Defrosting of the freezer

The freezer compartment of this model, on
the other hand, is a "no frost" type. This
means that there is no buildup of frost
when it is in operation, neither on the inter-
nal walls nor on the foods.
The absence of frost is due to the continu-
ous circulation of cold air inside the com-
partment, driven by an automatically con-
trolled fan.
Important! There are some sounds during
normal use (compressor, refrigerant
circulation).
Check if the appliance stands sta-
ble (all the four feet should be on
the floor).
Set a warmer temperature.
Refer to "Closing the door".
Do not keep the door open longer
than necessary.
Let the product temperature de-
crease to room temperature be-
fore storage.
Decrease the room temperature.
Refer to "Action Freeze function".
This is correct.
Clean the water outlet.
Make sure that products do not
touch the rear plate.
electrolux 17
Solution

Advertisement

Table of Contents
loading

Table of Contents