Desa E32L Owner's Operation And Installation Manual page 19

Table of Contents

Advertisement

Base
Cover
Figure 34 - Removing Base Cover
SERvICING FAN BLOWER
To remove fan blower:
1. Follow instructions under Accessing Imag-
ing Unit, page 18.
2. Remove 3 light bulbs from lamp fixtures
(see Replacing Light Bulbs, page 16).
3. Disconnect two 1/4" blade connectors at
from posts on motor unit.
4. Remove 4 hex nuts and washers located
on blower mounts at base of cabinet (see
Figure 35).
Hex.Nut
Washer
Spacer
Screw
Fan Assembly
Posts for Blade
Connectors
Figure 35 - Removing Fan Assembly (Shown without Firebox for Clarity)
111076-01F
MAINTENANCE
Continued
5. Lift entire fan assembly off of mounts and
6. Remove screws with washers and hex
7. Mount new fan to blower mount in reverse
8. Slide blower assembly with spacers over
9. Attach blade connectors to posts on motor
.
SERvICING FLAME PENNANTS
If flame pennants should become tangled or
detached reattach or replace.
1. Locate affected flame pennant. Slip hem
2. Pull flame cord up to proper hook location,
3. Tie another knot over slip knot and trim
Washer Hex.
Blower
Nut
Mount
(1 of 4)
www.desatech.com
tilt out of unit.
nuts from fan housing.
order.
mounting lugs and replace washer and
nut at each lug. Do not over tighten.
mount.
Note: Wire connectors for fan motor are
non-polarized and may be connected to
either terminal for proper operation.
at base of flame pennant over proper
hanger bracket position. See Figure 36,
page 20, for proper location.
use a slip knot to adjust cord length and
attach cord to hook.
away excess cord.