Troubleshooting; Unit Will Not Run; Compressor Cycles Intermittently - Cornelius SERIES 750 (R404a Service Manual

Modular flaked ice maker
Table of Contents

Advertisement

Trouble

UNIT WILL NOT RUN

COMPRESSOR CYCLES
INTERMITTENTLY.

TROUBLESHOOTING

Probable Cause
A.
On–off switch in "off" position.
B.
Defective on–off switch.
C.
Blown fuse.
D.
Thermostat set too warm for
ambient.
E.
Power relay contacts
corroded.
F.
Defective thermostat.
G.
Loose electrical connection.
H.
Gearmotor overload protector
has cut off machine.
A.
Low voltage.
B.
Dirty condenser.
C.
Air circulation restricted.
D.
Defective condenser fan
motor.
E.
Defective relay, overload
protector or starting capacitor.
F.
Loose electrical connection
23
Remedy
A.
Turn switch to "on".
B.
Check and replace.
C.
Replace fuse and check for cause
of blown fuse.
D.
Adjust colder.
E.
Check and clean.
F.
Check and replace.
G.
Check wiring.
H.
Turn switch to off then to on.
A.
Check line voltage.
B.
Clean condenser.
C.
Remove restriction.
D.
Check and replace.
E.
Check and replace.
F.
Check wiring.
166240009