Ext -100 Control Panel; Bext; Ext -100H Control Panel - Clarke BEXT 100H Operator's Manual

Hide thumbs Also See for BEXT 100H:
Table of Contents

Advertisement

Page 16
5. If the extractor removes an excess amount of foam
from the carpet, add a de-foamer such as Clarkare
De-foamer Concentrate to the recovery tank. The
amount needed will vary according to the amount of
detergent already in the carpet.
CAUTION:
To prevent damage, use a water-based de-
foamer rather than an oil-based de-foamer.
CAUTION:
Do not leave the extractor or other cleaning
machines or tools on the carpet when not
in use. Cleaning solution in the machines
and tools can leak onto the carpet and
cause light spots or stains.
NOTE:
To order Clarkare
part no. 398421. To order Clarkare
order part no. 398420.
For instructions for preparation and operation of your floor
tool, read the instruction sheet given with your floor tool.
B
EXT
®
-100 Control Panel
1
VAC
VACUUM SWITCH (1 ): The vac switches illuminate when turned
on.
PUMP SWITCH (2): This switch will illuminate when the pump
is on.
B
EXT
®
-100H Control Panel
2
VAC
CIRCUIT LOCATOR (1): When this light is on, it indicates that cord
#2 is on a separate line from cord #1. Cord #2 supplies voltage
to the heater allowing it to heat to the proper temperature range.
VACUUM SWITCH (2): The vacuum switch will illuminate when
the vacuum motor is turned on.
PUMP SWITCH (3): This switch will illuminate when the pump
is on.
HEAT SWITCH (4): The heat switch will illuminate when it is
activated and will turn the heater on.
®
Clarke
B
®
EXT
-100, 100H 150H, 300HV Operator's Manual
®
Extractor Concentrate, order
®
Defoamer,
2
PUMP
Figure 4
1
LOCATOR
3
4
PUMP
HEAT
Figure 5
®

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bext 120vBext 150hBext 300hvBext 100

Table of Contents