Epson Stylus Photo Service Manual page 124

Color ink-jet printer
Hide thumbs Also See for Stylus Photo:
Table of Contents

Advertisement

EPSON Stylus Photo
Table 5-11. Repair of the Printer Mechanism (Continued)
Symptom
Abnormal paper
Paper is not fed.
feeding.
Printing start point is
not right.
Printer stops during
Fatal error appears. ASF sensor is
initialization.
Rev. A
Condition
Causes
Friction of the PF
roller.
Abnormal operation
of the hopper.
Malfunction of ASF
drive change-over.
Friction of the PF
roller.
defective.
PE sensor is
defective.
HP sensor is
defective.
Head FFC is
disconnected.
CR motor is
defective.
PF motor is
defective.
Checkpoint
Check if the PF
Clean the PF roller
roller rotates when
by the cleaning
paper is not fed.
sheet. Replace the
PF roller if it does
not recover.
Check movement of
Replace ASF.
the ASF hopper
visually.
Check if the ASF
Replace gears of
gear rotates visually.
the ASF drive
change-over.
Check if the PF
Clean the PF roller
roller slips during
by the cleaning
paper feeding.
sheet. Replace the
PF roller if it does
not recover.
Check the signal
Replace ASF
level of the ASF
sensor.
sensor.(Refer to
Table 5-2)
Check the signal
Replace PE sensor.
level of the PE
sensor.(Refer to
Table 5-2)
Check the signal
level of the HP
sensor .(Refer to
Table 5-2.)
Check if the head
Connect the head
FFC is connected.
FFC.
Check the CR motor
Replace the CR
cable is connected.
motor if there is no
problem in the cable
connection.
Check if the PF
Replace the PF
motor cable is
motor if there is no
connected.
problem in the cable
connection.
Solution
5-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents