EPL-N2700 Optional Units
2.2 Disassembly and Assembly of the Duplex Unit
2.2.1 Duplex Unit Door Set Sensor Removal
1. Remove the Duplex Unit. (Refer to Section 2.1.)
2. Open the Duplex Unit Door.
3. Remove the stopper securing the door set sensor to the Duplex Unit
Frame and unhook the sensor from the frame.
4. Disconnect the harness from the connector on the sensor.
Figure 2-6. Paper Take-up Roller Removal
Duplex Unit
Disassembly and Assembly of the Duplex Unit
Revision A