4. Maintenance

4.1 Cleaning

16
Caution Risk of Injury !
Turn the main switch off.
Maintenance work on the unit may only be conducted with the machine
turned off.
A clean machine protects against malfunctions !
Daily cleaning:
Particularly the areas around the needle thread guides and
tensions, thread controller spring and hook are to be cleaned of
sewing dust and lint accumulations (e.g. with a compressed air
gun).
For cleaning the parts attached under the foundation plate tilt the
machine head to the side.
Clean the motor ventilator grill 1 with a compressed air gun.
Check the water level in the pressure regulator.
The water level should not be allowed to rise to the filter insert 2.
After screwing in the drain screw 4 blow the water out of the water
separator 3 under pressure.
Dirt and condensation water are eliminated through the filter insert 2.
Wash out the dirty filter bowl and filter insert with naphtha after a
certain period of operation and blow clean with compressed air.
ATTENTION !
Do not use solvents for washing!
They destroy the filter bowl.
1
2
3
4