Chamberlain HD920EV Owner's Manual page 26

Belt drive battery backup
Hide thumbs Also See for HD920EV:
Table of Contents

Advertisement

Installation
STEP 14 Wire the Safety Reversing Sensors (continued)
OPTION B
PRE-WIRED INSTALLATION
1. Cut the end of the safety reversing sensor wire, making sure there is enough wire to reach the
pre-installed wires from the wall.
2. Separate the safety reversing sensor wires and strip 7/16 inch (11 mm) of insulation from each
end. Choose two of the pre-installed wires and strip 7/16 inch (11 mm) of insulation from each
end. Make sure that you choose the same color pre-installed wires for each sensor.
3. Connect the pre-installed wires to the sensor wires with wire nuts making sure the colors
correspond for each sensor. For example, the white wire would connect to the yellow wire and
the white/black wire would connect to the purple wire.
4. At the garage door opener, strip 7/16 inch (11 mm) of insulation from each end of the wires
previously chosen for the safety reversing sensors. Twist the like-colored wires together.
5. Insert the wires connected to the white safety sensor wires to the white terminal on the garage
door opener. Insert the wires that are connected to the white/black safety sensor wires to the
grey terminal on the garage door opener.
1
Pre-installed
Safety reversing
wires
sensor wires
3
Safety reversing
sensor wires
White
White/Black
4
Yellow
7/16" (11 mm)
25
2
Not Provided
Pre-installed wires
Yellow (for example)
Purple (for example)
5
Yellow
(for example)
Purple
To insert or remove the wires from
the terminal, push in the tab with a
screwdriver tip.
7/16"
(11 mm)
Purple
(for
example)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd930evLw5000evWd962kevWd962kpevWd962mlev349544

Table of Contents