Miscellaneous Error Messages - Lenovo ThinkCentre M71e Hardware Maintenance Manual

Machine types: 3129, 3132, 3133, 3134, 3136, 3140, 3141, 3143, 3146, 3147, 3150, 3154, 3156, 3157, 3166, 3167, 3169, 3171, 3175, 3176, 3177, 5033, 5036, 5039, 7338, and 7339
Hide thumbs Also See for ThinkCentre M71e:
Table of Contents

Advertisement

POST Error code
0189
System Security - Can not read the
Security EEPROM
0197
System Security - Unauthorized security
data change detected
0190
System Security - Invalid security change
requested
0199
System Security - Security password retry
count exceeded

Miscellaneous error messages

Message/Symptom
Changing display colors
Computer will not power-off. See "Hard disk drive boot
error" on page 49.
Computer will not RPL from server
Computer will not perform a Wake on LAN (if applicable)
Dead computer. See "Hard disk drive boot error" on page
49.
Diskette drive in-use light remains on or does not light
when drive is active.
POST Error message
Description/Action
This error message indicates that the Security
EEPROM may be broken or removed.
Press F1 to enter the Setup Utility program.
Then press F10 to save and exit the Setup Utility
program.
Press F1 to enter the Setup Utility program.
Then press F10 to save and exit the Setup Utility
program.
Press F1 to enter the Setup Utility program.
Then press F10 to save and exit the Setup Utility
program.
Press F1 to enter the Setup Utility program.
Then press F10 to save and exit the Setup Utility
program.
FRU/Action
Display/Monitor
1. Power Switch
2. System Board
3. Riser card, if installed
1. Ensure that network is in startup sequence as first
device or first device after diskette
2. Ensure that network adapter is enabled for RPL
3. Network adapter (Advise network administrator of
new MAC address)
1. Check power supply and signal cable connections
to network adapter
2. Ensure that the operating system settings are set to
enable Wake on LAN
3. Ensure Wake on LAN feature is enabled in
Setup/Configuration (see "Starting the Setup Utility
program" on page 43)
4. Ensure network administrator is using correct MAC
address
5. Ensure no interrupt or I/O address conflicts
6. Network adapter (advise network administrator of
new MAC address)
1. Power Supply
2. System Board
1. Diskette Drive
2. System Board
3. Diskette Drive Cable
Chapter 7
.
Symptom-to-FRU index
69

Hide quick links: