Programming Compulsory And Clerk Control Function - Casio PCR-360 Operator's Instruction Manual

Hide thumbs Also See for PCR-360:
Table of Contents

Advertisement

Programming compulsory and clerk control function

About compulsory, clerk control function...
The following procedure lets you program a number of functions.
• Use o key as "Clerk" key/"Open" key.
• Assign "00"key/Assign "000" key.
• Reset/Not reset (to 0001) the consecutive number when the Daily RESET report is issued.
• Required/Not required to input the cash in drawer amount before the daily READ/RESET report.
(M
D
)
ONEY
ECLARATION
• Prohibit/Allow the cancel operation.
• Force S key operation before finalization.
• Clear the key buffer when the transaction is terminated.
• Display Hour/Minute/Second or Hour/Minute on time display.
*1
Effective only after all RESET reports are issued.
Programming procedure
———————————————————————————————————————————————————
Use "Clerk"function/Use "Open" function
——————————————————————————————————————————————
Assign "00" key/Assign "000" key
———————————————————————————————————————————————————
Reset/Not reset the consecutive number
————————————————————————————————————————
Prohibit/Allow the cancel operation.
——————————————————————————————————————————————
Force S key operation before a finalization
——————————————————————————————————
Required/Not required to input the cash in drawer
amount before the Daily report
————————————————————————————————————————
Clear the key buffer when the
transaction is terminated
—————————————————————————————
Display "seconds" during time display.
——————————————————————————————————
PGM
A-A08
X
CAL
Z
REG
OFF
RF
PGM
Mode Switch
*1
Not clear = 0
g
Clear = 1
Suppress = 0
h
Display = 4
6 £S 6 º§™™S 6
57
default
Reset = 0
c
Non reset = 2
Allow = 0
d
Prohibit = 4
No = 0
e
:
Compulsory = 2
Not required = 0
f
(e+f)
Required = 4
:
(g+h)
: : : :
Open = 0
a
:
Clerk = 1
"00" = 0
b
(a+b)
"000" = 4
:
(c+d)
6 C 6 S

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents