* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article
336-26. If other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger
than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.
** Time-delay fuse or circuit breaker.
†† Charge quantity is for 15 ft of interconnecting tubing. For tubing lengths longer than 15 ft, add 0.6 oz of refrigerant per ft of tube length in excess of 15 ft.
‡‡ Do not use hard shutoff TXV with LSV.
*** See low-ambient controller Installation Instructions for application.
††† Fan motor with ball bearings required.
NOTES: 1. All motors/compressors contain internal overload protection.
2. Copper wire must be used from service disconnect to unit.
3. Control circuit is 24v on all units and requires external power source.