WARNING:
during handling do not push or pull the unit: it may tip over or be
damaged.
B.1.2.2 Disposing of the packing
Packing materials should be disposed of accordance with the
binding laws in the country where the appliance is to be used.
Recyclable plastic parts are marked as follows:
polythene:outer wrapping, instructions booklet bag
PE
polypropylene: straps
PP
polystyrene foam: protective surround elements
PS
pressed board: protective surround elements
B.2 TECHNICAL DATA
B.2.1 MATERIALS AND FLUIDS USED
All areas designed to come into contact with food are in steel
or covered in non-toxic plastic material. An HFC refrigerant, in
compliance with current legal standards, is used in the refrig-
erating units. The type of refrigerant gas used is stated on the
data plate.
B.2.2 DIMENSIONS, PERFORMANCE AND CONSUMPTION
External dimensions:
- Width
- Depth with door closed
- Depth with door open
- Height
Chamber dimensions:
- Width
- Depth
- Height
Gross capacity
Power supply
Internal temp. range
Max. ambient temp.
Current input (°)
Refrigerant charge R134a
Refrigerant capacity (R134a) (¹)
Refrigerant capacity (R134a) (²)
No. and type of defrostings (*)
(°) At room temperature 104°F/40°C.
(¹) At room temperature 89.6°F/32°C, condensation
temperature 131°F/+55°C and evaporation temperature
14°F/-10°C.
(²) ASHRAE PERFORMANCE ambient temperature 89.6°F/
+32°C, condensation temperature 131°F/+55°C and
evaporation temperature 44.96°F/+7.2°C.
(*) Auto (by electronic board)
29.53"
750mm
38.38"
975mm
65.35"
1660mm
83.07"
2110mm
24.80"
630mm
34.25"
870mm
66.81"
1697mm
245.68 gal
930 Iiters
120V 1Ph 60Hz
+32°F/+50°F
0°C/+10°C
+109.4°F
0.595lbs
1137 W
min 1 each 24h x max 30'
B.2.3 PHYSICAL SAFETY FEATURES, HAZARDS
The appliance has no sharp or projecting parts.
The guards for the mobile and live parts are bolted on to the
cabinet to prevent accidental access.
B.2.4 POSITIONING
Install the equipment, taking all the safety precautions
required for this type of operation, also respecting
the relevant fire-prevention instructions.
Place the appliance in a ventilated room and away
from heat sources such as radiators or air-
conditioning systems, in order to allow the cooling
of the refrigerating unit components.
Never cover the condenser, not even temporarily, as
this may jeopardise the operation of both the
condenser and the appliance.
Make sure to position the appliance taking into consideration
the space needed for door opening.
Pay particular attention to levelling of the floor on which the
appliance stands, in order to ensure its optimal operation.
IMPORTANT:
level the appliance, otherwise its operation could be compro-
mised. The appliance must be sealed to the floor with silicone.
ADVICE:
the part of the floor on which the cabinet is placed should be
physically insulated from the rest of the supporting surface
by means of suitable thermal insulating material, and when
possible, by means of a heat barrier.
For optimum appliance operation, please follow recommended
spacing for equipment:
+43°C
8 A
270 gr
526 W
11