Main Technical Characteristics; Einstallation And Assembly; Introduction; Customer's Responsibilities - Electrolux ecostore 727419 Installation Manual

Vertical refrigerators
Table of Contents

Advertisement

R404a(GWP:3922)/R407a(GWP:2107)) or HC refrigerant fluid
for models with refrigerant R290, complying with the current
regulations, is used in the refrigerating units. The type of gas
D.2

Main technical characteristics

Rack dimensions mm
Gross capacity L
Power supply voltage V
1.
Depending on the model
Positive temperature ventilated models with fully insulated door
Positive temperature ventilated models with glass door
Negative temperature ventilated models with fully insulated door
Positive temperature ventilated models with glass door
Low temperature ventilated models with fully insulated door
Low temperature ventilated models with glass door
Ventilated models with separate refrigerator compartments and fully insulated door
Ventilated models with separate refrigerator/freezer compartments and fully insulated door
E
INSTALLATION AND ASSEMBLY
E.1

Introduction

WARNING
Refer to "Warning and Safety
Information".
To ensure correct operation of the appliance and maintain safe
conditions during use, carefully follow the instructions given in
this chapter.
Check and, if necessary, level the appliance after positioning.
Incorrect levelling can cause appliance malfunctioning.
CAUTION
Before moving the appliance make sure
the load bearing capacity of the lifting
equipment used is suitable for its weight.
NOTE!
Appliances with incorporated refrigerating unit
must be handled upright. If the appliance is
handled in a horizontal position, make sure to wait
a few hours in upright position before making it
operational.
CAUTION
• Install the appliance in a ventilated
place, away from heat sources such
as radiators or air conditioning systems,
to allow correct cooling of the refriger-
ating unit components.
• Never cover the condenser, even tem-
porarily, as this can compromise its
proper operation and therefore that of
the appliance.
• The machine must be taken to the
place of installation and removed from
the packing base only when being
installed.
530x530
700 (1 module)
1400 (2 modules)
1
230V/50Hz
1
220V/60Hz
1
220–240V/50Hz
Temperature range in compartment
used is given on the data plate. The CO2 equivalent of the gas
may be calculated multiplying GWP value by quantity of gas.
E.2

Customer's responsibilities

The tasks and works required of the Customer are:
• check the floor planarity on which the appliance is placed;
• arrange an earthed power socket of suitable capacity for the
input specified on the data plate;
• provide a high sensitivity manual-reset differential thermal
magnetic switch;
NOTE!
For information regarding the electrical connection,
refer to "A.11 Electrical connection".
E.3

Unpacking instructions

Unpack the appliance carrying out the following
operations:
• if present, cut the straps and remove the protective film,
taking care not to scratch the surface if scissors or blades
are used;
• if present, remove the cardboard top, the polystyrene
corners and the vertical protection pieces;
• for appliances with stainless steel surfaces, remove the
protective film very slowly without tearing it, to avoid leaving
glue stuck to the surface;
• should this happen, remove the traces of glue with a non-
corrosive solvent, rinsing it off and drying thoroughly;
• it is advisable to go over all the stainless steel surfaces with
a rag soaked in paraffin oil in order to create a protective film.
E.4

Disposal of packing

The packing must be disposed of in compliance with the
current regulations in the country where the appliance is used.
All the packing materials are environmentally friendly.
They can be safely kept, recycled, or burned in an appropriate
waste incineration plant. Recyclable plastic parts are marked
as follows:
0/+6
0/+6
-2/+10
+2/+10
-22/-15
-20/-15
-2/+10
-2/+10
-2/+10
-22/-15
27

Advertisement

Table of Contents
loading

Table of Contents