4.11

Parameter Setting

4.11.1 Parameter setting/display
Function: Setting and displaying parameters held by IOT in NVM
Operation procedure:
1.
Enter the Diag. (C/E) mode.
2.
Select [CE Maintenance Parameter] with the
3.
Press the Form Feed/Set button to advance to setting/display parameter selection in
[CE Maintenance Parameter].
4.
Select a setting/display parameter with the
(For the setting/display parameters, refer to the table below.)
5.
Press the Form Feed/Set button to display the setting/display parameter.
Example: Scan Regi Tray1 display screen
6.
Select setting data from the setting range with the
7.
Press the Form Feed/Set button to write the setting data into NVM.
Example: Post-change screen
8.
When displaying and setting each life, have the life item displayed and press the
Form Feed/Set button.
Example: Life Fuser display screen
9.
Press the Form Feed/Set button to display data (decimal).
Setting/display parameters
Item
Paper feed direction
registration adjustment
Scan direction registration
adjustment
Life counter
and
and
Scan Regi Tray1
Scan Regi Tray1
Life Fuser
Life Fuser
Range
Sets the paper feed direction
-128 127
registration
Sets the scan direction registration of
-128 127
Main, Aux 1, Aux 2, MSI, and Dup.
Reads and initializes the fuser and
printer life counters.
V-53
buttons.
buttons.
4*
and
buttons.
6
Reading
6666
Description