PREPARING FOR INSTALLATION
1
OF NEW DRYER
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust.
DISCONNECTING GAS
TURN GAS
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
SHUT-OFF
OLD DUCTING MATERIAL.
VALVE TO THE
REPLACE WITH NEW CSA(AGA)
OFF POSITION.
APPROVED FLEXIBLE GAS LINE
CONNECTOR AND UL APPROVED
TRANSITION DUCT.
WARNING
NEVER REUSE OLD FLEXIBLE
CONNECTORS.
connectors when installing gas appliances.
REMOVING LINT FROM WALL EXHAUST
OPENING
Remove and discard existing plastic or metal foil transition
duct and replace with UL listed transition duct.
INTERNAL
DUCT
OPENING
ADJUSTING FOR ELEVATION
operation and need not be adjusted for operation at or below
2000 ft. elevation. For operation at elevations above 2000 ft.,
input ratings should be reduced at a rate of 4 percent for each
1000 ft. above sea level.
in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.
Installation Instructions
WALL
CHECK THE EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY
TILT THE DRYER
SIDEWAYS AND
REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE
DRYER LEGS.
BE SURE TO REMOVE
ALL OF THE FOAM
PIECES AROUND
THE LEGS.

GAS REQUIREMENTS

2
WARNING
The installation must conform with local codes, or in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA
54, or the Natural Gas and Propane Installation Code, CSA B149.1.
This gas dryer is equipped with a Valve & Burner Assembly for use
only with natural gas. Using a conversion kit WE25M87 your local
service organization can convert this dryer for use with propane
(LP) gas.
ALL CONVERSIONS MUST BE MADE BY PROPERLY TRAINED AND
QUALIFIED PERSONNEL AND IN ACCORDANCE WITH LOCAL CODES AND
ORDINANCE REQUIREMENTS.
The dryer must be disconnected from the gas supply piping system
during any pressure testing of that system at a test pressure in
excess of 0.5 PSI (3.4 KPa).
The dryer must be isolated from the gas supply piping system by
closing the equipment shut-off valve during any pressure testing
of the gas supply piping of test pressure equal to or less than
0.5 PSI (3.4 KPa).
WARNING
Explosion Hazard
If connected to LP gas, have a qualified person make sure gas
pressure does not exceed 13" water column.
Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
DRYER GAS SUPPLY CONNECTION
3 11/32
1 25/32
GAS SUPPLY
A 1/8 in. National Pipe Taper thread plugged tapping, accessible
for test gauge connection, must be installed immediately
upstream of the gas supply connection to the dryer. Contact
your local gas utility should you have questions on the installation
of the plugged tapping.
Supply line is to be 1/2 in. rigid pipe and equipped with an acce-
sible shut-off within 6 ft.of, and in the same room with the dryer.
Use pipe thread sealer compound appropriate for natural or
(listed connector ANSI Z21.24 / CSA 6.10). The length of the
connect shall not exceed 3 ft.
3
Fire Hazard
Use a new CSA Interna-
tional approved flexible
gas supply line.
Never reuse old flexible connectors.
Install a shut-off valve.
Securely tighten all gas connections.
3/8 NPT MALE
THREAD GAS
SUPPLY
NOTE: Add to vertical dimension the
distance between cabinet bottom to floor
ply.