clock command

Syntax
clock [options]
options:
-d mm/dd/yyyy
-t hh:mm:ss
-g gmt offset
-dst on/off/special case
Description
Use the clock command to display the current date and time according to the IMM
clock and the GMT offset. You can set the date, time, GMT offset, and daylight
saving time settings.
Note the following information:
v For a GMT offset of +2 or +10, special daylight saving time settings are required.
v For +2, the daylight saving time options are as follows: off, ee (Eastern Europe),
v For +10, the daylight saving time settings are as follows: off, ea (Eastern
v The year must be from 2000 to 2089, inclusive.
v The month, date, hours, minutes, and seconds can be single-digit values (for
v GMT offset can be in the format of +2:00, +2, or 2 for positive offsets, and -5:00
Example
system> clock
12/12/2003 13:15:23 GMT-5:00 dst on
system> clock -d 12/31/2004
ok
system> clock
12/31/2004 13:15:30 GMT-5:00 dst on

identify command

Syntax
identify [options]
options:
-s on/off/blink
-d seconds
Description
Use the identify command to turn the chassis identify LED on or off, or to have it
flash. The -d option can be used with -s on to turn the LED on for only for the
number of seconds specified with the -d parameter. The LED then turns off after
the number of seconds elapses.
Example
system> identify
-s off
system> identify -s on -d 30
ok
system>
92
Integrated Management Module: User Guide
gtb (Great Britain), egt (Egypt), fle (finland).
Australia), tas (Tasmania), vlad (Vladivostok).
example, 9:50:25 instead of 09:50:25).