DC Operation
The DC terminals may ONLY be used for charging 12 volt automotive-type
batteries .
Connecting the battery cables:
1. Before connecting charging cables to a battery that is installed in a vehicle,
disconnect the vehicle's grounded battery cable.
. -
m
The battery gives off explosive
gases; keep sparks,
!
flames and cigarettes away. Provide adequate ventilation when charging
or using batteries.
2. Connect the positive (+) battery cable to the battery positive (+) terminal.
3. Connect the other end of the positive (+) battery cable to the generator
positive (+) terminal.
NEGATIVE
DC CIRCUIT
TERMINAL
PQSITIVE TERMINAL
4. Connect the negative (-) battery cable to the battery negative (-) terminal.
5. Connect the other end of the negative (-) battery cable to the generator
negative (-) terminal.
6. Start the generator.
piimq
Do not start the vehicle while the battery charging cables
are connected
and the generator
is running.
The vehicle or the
generator may be damaged.
An overloaded DC circuit, excessive current draw by the battery, or a wiring
problem will trip the DC circuit protector (PUSH button extends out). If this
happens, wait a few minutes before pushing in the circuit protector to resume
operation. If the circuit protector continues to go OFF, discontinue charging
and see your authorized Honda generator dealer.