Oil Alert System
The Oil Alert system is designed to prevent engine damage caused by an
insufficient
amount of oil in the crankcase.
Before the oil level in the
crankcase can fall below a safe limit, the Oil Alert system will automatically
shut down the engine (the engine switch will remain in the ON position). If the
Oil Alert system shuts down the engine, the Oil Alert lamp will flash when you
operate the starter, and the engine will not start. If this occurs, add engine oil
(P.20).
OIL ALERT LAMP
DC Terminals
The DC terminals
may ONLY be used for charging
12
volt automotive type
batteries.
The terminals are colored red to identify the positive (+) terminal and black
to identify the negative (-) terminal. The battery must be connected to the
generator DC terminals with the proper polarity (battery positive to generator
red terminal and battery negative to the generator black terminal).
DC Circuit Protector
The DC circuit protector automatically
shuts off the DC battery charging
circuit when the generator is overloaded, when there is a problem with the
battery or the connections
between the battery and the generator
are
improper.
DC CIRCUIT