AT&T SPIRIT 308 Product Information Manual

AT&T SPIRIT 308 Product Information Manual

Communications systems
Hide thumbs Also See for SPIRIT 308:

Advertisement

SPIRIT
308/616
COMMUNICATION SYSTEMS
Product Information Guide
AT&T
SERVICES DIVISION EDUCATION
MAY 1987
Select Code 999-903
Copyright © 1987 AT&T
AT&T PROPRIETARY
Use Pursuant to Company Instructions

Advertisement

Table of Contents
loading

Summary of Contents for AT&T SPIRIT 308

  • Page 1 SPIRIT 308/616 ™ COMMUNICATION SYSTEMS Product Information Guide AT&T SERVICES DIVISION EDUCATION MAY 1987 Select Code 999-903 Copyright © 1987 AT&T AT&T PROPRIETARY Use Pursuant to Company Instructions...
  • Page 2 SPIRIT™ MODEL 308/616 COMMUNICATIONS SYSTEM Product Information Guide AT&T Technical Training Services Dublin, Ohio...
  • Page 3 First Edition February 1987 Developed by AT&T Technical Training Services 5151 Blazer Memorial Parkway Dublin, Ohio 43017-1392 © 1987 AT&T Technical Training Services. All rights reserved. This material may not be reproduced, stored in a retrieval system, or transmitted in whole or in part, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of the publisher.
  • Page 4: Table Of Contents

    Product Information Guide T217 TABLE OF CONTENTS Page OVERVIEW SYSTEM CONFIGURATION SPIRIT COMPETITION SYSTEM DOCUMENTATION GROUNDING REQUIREMENTS INSTALLATION SPIRIT WIRING PLAN PIN ASSIGNMENTS MODULAR WIRING EXTERNAL PAGING EQUIPMENT AUXILIARY LINES EXTERNAL ALERT MULTIFUNCTION STATION SETS INITIAL SYSTEM TEST FEATURE TONES AND RINGING SPEEDCALLING SPIRIT FEATURE ADMINISTRATION SYSTEM MAINTENANCE...
  • Page 5 T217 Product Information Guide LIST OF FIGURES FIGURE 1 - SPIRIT SYSTEM CONFIGURATION FIGURE 2 - SPIRIT COMPETITION MATRIX FIGURE 3 - TYPICAL SPIRIT WIRING PLAN FIGURE 4 - MODULAR WIRING FIGURE 5 - SBDS WIRING MATERIALS FIGURE 6 - PAGING SYSTEM WIRING FIGURE 7 - EXTERNAL ALERT INTERFACE FIGURE 8 - 24-BUTTON MULTIFUNCTION STATION SET FIGURE 9 - SYSTEM ADMINISTRATION OVERLAY MODEL...
  • Page 6: Overview

    Product Information Guide T217 SPIRIT™ MODEL 308/616 COMMUNICATlONS SYSTEM OVERVIEW The SPIRIT Model 308/616 CS is a low-cost, high-quality, high-reliability product with fixed features and modular equipment. AT&T is the only company offering a system with a full range of features and services in one package: Call Pick-Up Idle-Line Preference Hands-Free Answering Intercom...
  • Page 7: Figure 1 - Spirit System Configuration

    Product Information Guide T217 2500 SET POWER FAILURE 616 EXPANSION UNIT 308 CONTROLLER 24-BUTTON SET MUSIC PUBLIC ADDRESS NETWORK INTERFACE EXTERNAL 6-BUTTON SET ALERTER 217-3 2/87 1 FIGURE 1 - SPIRIT SYSTEM CONFIGURATION AT&T – PROPRIETARY...
  • Page 8: System Configuration

    Product Information Guide T217 SYSTEM CONFIGURATION The 308 SPIRIT CS is the smallest configuration; it has up to three CO lines and eight station lines. Adding the optional expansion unit allows growth up to six CO lines and sixteen stations, yielding the 308/616 Spirit system. The model 308 control unit consists of a textured, gray plastic housing and base, enclosing the PWB (printed wiring board) and power supply.
  • Page 9: Figure 2 - Spirit Competition Matrix

    T217 Product Information Guide TOSHIBA AT&T FEATURE STRATA ULTRACOM ARIES SPIRIT 308/616 CO LINES STATIONS INTERCOM PATHS SPEAKERPHONE CONFERENCE w/DROP 7 0 # 100# SYSTEM SPEEDCALL PERSONAL SPEEDCALL DO NOT DISTURB TRANSFER HFAI/DISABLE STATION MSG ACTIVATION MUSIC-ON-HOLD INTERFACE PAGING INTERFACE PROGRAMMABLE FEATURES IDLE LINE PREFERENCE RINGING LINE PREFERENCE...
  • Page 10: Spirit Competition

    Product Information Guide T217 SPIRIT COMPETITION The SPIRIT CS faces major competition for small business customers needing an electronic key telephone system. Three companies; TIE, ITT, and TOSHIBA, are top competitors with systems in that communications market. A feature-comparison matrix is shown on the opposite page.
  • Page 11: Grounding Requirements

    Product Information Guide T217 GROUNDING REQUIREMENTS Proper grounding is fundamental as protection against lightning/power surges, power crosses on CO lines, and static discharge to equipment. The green-wire ground of the AC outlet is the only ground serving the SPIRIT system. It must be connected to the building ground.
  • Page 12: Installation

    Product Information Guide T217 INSTALLATION The following procedures are required to install a SPIRIT CS, and the customer pays for them in the installation charge: Install the control unit - Special consideration should be given to: Local telco CO line terminations (within 25 feet) Nearest AC outlet for the control unit (within 6 feet) Access for administration, future growth, and changes Allowing for proper ventilation (21 inches clearance)
  • Page 13: Spirit Wiring Plan

    T217 Product Information Guide SPIRIT WIRING PLAN The SBDS (Small-Business Distribution System) wiring plan for the SPIRIT is the same plan used for the MERLIN CS. The SPIRIT system requires two-pair wiring, but four-pair wiring is used to facilitate migration to four-pair systems in the future. Unlike MERLIN CS control units, SPIRIT control units ship WITHOUT 267C adapters.
  • Page 14: Figure 3 - Typical Spirit Wiring Plan

    Product Information Guide T217 103A, 104A, 105A, 630B CONNECTING Z601A COLOR CODES FOR 4–PR. BLOCK ADAPTER DIW CABLE OR DW8A-SE CORD Z601A 103A, 104A, 105A, COLOR CODES FOR 3–PR. ADAPTER 630B CONNECTIN6 DISTRIBUTION CABLE BLOCK ( H-STATION WIRE ) 625, 725, 630B, Z601A COLOR CODES FOR 4–PR.
  • Page 15: Figure 4 - Modular Wiring

    T217 Product Information Guide CONTROLLER POWER CORD GREEN–WIRE GROUND AC OUTLET ADD SURGE PROTECTOR WHERE APPROPRIATE JUMPER CORDS PLUGGED INTO THE JACK FIELD AND INTO THE CONTROL UNIT D4CH NETWORK INTERFACE JACK RJ11, RJ14, OR RJ21 A JACK F1ELLD INSTALLED Z122C NEAR YOUR CONTROL APPARATUS BOXES...
  • Page 16: Modular Wiring

    Product Information Guide T217 MODULAR WIRING The method of connection depends on the building wiring termination. Use the following station and distribution wire: Tinsel Cord - A 2-pair double-ended modular cord used primarily for sets. D-Station Wire - A 22-gauge, two-pair distribution wire. H-Station Wire - A 24-gauge, three-pair distribution wire.
  • Page 17 T217 Product Information Guide NOTES...
  • Page 18: Figure 5 - Sbds Wiring Materials

    Product Information Guide T217 ITEM DESCRIPTION COMCODE 103A-50 Connecting Block 103104220 102605136 258A 25-pair to Mod. Adapter 103732541 D2R-29 Mounting Cord 7 foot D2R-29 Mounting Cord 14 foot 103732566 103732582 D2R-29 Mounting Cord 25 foot 102479904 D4BU-29 Mounting Cord 7 foot 102479896 D4BU-29 Mounting Cord 14 foot...
  • Page 19: Figure 6 - Paging System Wiring

    T217 Product Information Guide CONTROLLER PAGE SIX–POSITION MODULAR CORD 25' RCA–ENDED WIRING LABEL CORD PAGE INPUT Y CONNECTOR MUSIC IN MALE–MALE POWERMATE RCA–ENDED 25' RCA-ENDED CORD CORD TUNER Y CONNECTOR SPEAKER 217-9 3/87 1 FIGURE 6 - PAGING SYSTEM WIRING AT&T –...
  • Page 20: External Paging Equipment

    Product Information Guide T217 EXTERNAL PAGING EQUIPMENT The PagePac 1 (for systems with optional public address system) is a loudspeaker paging system with 1-way transmission. Answerback paging is not supported by the SPIRIT CS. Typical hardware provided with the system is a PowerMate amplifier, speakers and wiring. The amplifier connects to the control unit via a 4-conductor, 6-position modular cord.
  • Page 21: Figure 7 - External Alert Interface

    T217 Product Information Guide 616 EXPANSION UNIT 308 CONTROLLER BELL 7–FOOT MODULAR CORD ( 4–WIRE ) DCI–48–48 6–POSITION 6–POSITION OUTPUT JACK INPUT JACK 25–FOOT MODULAR CORD ( 4-WIRE ) SUPPLIED WITH ALERTS 6–FOOT POWER CORD AC OUTLET 217-5 3/87 1 FIGURE 7 - EXTERNAL ALERT INTERFACE AT&T –...
  • Page 22: External Alert

    Product Information Guide T217 EXTERNAL ALERT The Wheelock DCI-48-48 is an interface unit for powering 48 V DC telephone bells, chimes, horns, strobes, and other external alerts for electronic key systems. The 6-position modular INPUT connects to the control unit ALERT jack while the 6-position OUTPUT connects to the alert device.
  • Page 23: Figure 8 - 24-Button Multifunction Station Set

    T217 Product Information Guide 6–BUTTON SET CS6501 24–BUTTON SET CS6502 217-2 2/87 1 FIGURE 8 - 24-BUTTON MULTIFUNCTION STATION SET AT&T – PROPRIETARY...
  • Page 24: Multifunction Station Sets

    Product Information Guide T217 MULTIFUNCTION STATION SETS The first six buttons on the 6-button and the 24-button sets correspond to the control unit TELCO LINE jacks. Buttons labeled 10 through 25 correspond to the sixteen control unit STATION jacks. These buttons are used for autodialing the 2-digit extension numbers on the 24-button set.
  • Page 25: Initial System Test

    T217 Product Information Guide INITIAL SYSTEM TEST Power is applied to the control unit through a line cord plugged into a standard 110 V AC outlet. A lighted green LED, visible in the upper left corner of the control unit, serves as the POWER ON indicator.
  • Page 26: Speedcalling

    Product Information Guide T217 SPEEDCALLlNG All speedcall numbers are assigned a 2-digit dial access code. There are two kinds of speedcall numbers: Personal numbers are assigned by individual station users, and are accessed with digits 10 through 25. Each user may store 16 speedcall numbers. System numbers are stored in the system memory and are accessed by all users.
  • Page 27: Figure 9 - System Administration Overlay Model

    Product Information Guide T217 ADMINISTRATION POWER SWITCH INDICATOR OPEN GRILLWORK 616 EXPANSION HEADER 308 CONTROL UNIT 616 CONTROL UNIT 217-4 3/2 1 FIGURE 9 - SYSTEM ADMINISTRATION OVERLAY MODEL 308/616 AT&T – PROPRIETARY...
  • Page 28: Spirit Feature Administration

    Product Information Guide T217 SPIRIT FEATURE ADMINISTRATION The system will function with the assigned default values when power is applied Changes may be administered to system features affecting each CO line appearance or each station set. If choices for programmable features are administered, each feature should be tested to assure proper operation.
  • Page 29: Figure 10 - Hardware Replacement Information

    T217 Product Information Guide MANUFACTURER’S COMMON DESCRIPTION DESCRIPTION COMCODE PEC CODE CNTRL-CS308A1 103985396 6030-308 308 CONTROLLER 103985404 60301 CNTRL-CS616A1 616 EXPANSION UNIT 3130-006 SET TEL-CS6501C01A-215 104372339 6-BUTTON SET 3130-024 24-BUTTON SET SET TEL-CS6502C01A-215 104372347 HANDSET K2N2-215 HANDSET 103985701 6' HANDCORD H4DU-215 104211305 12' HANDCORD...
  • Page 30: System Maintenance

    Product Information Guide T217 SYSTEM MAINTENANCE Read Pages 17 and 18 of the Customer Installation Instructions. You will have a hands-on exercise to try these tests when you attend class. CAUTION: Initiating system self-test interrupts call-processing. Control unit self-tests are made at connector location 10 from the ADMIN mode. Software changes/corrections cannot be made in the field: all software-related problems are cleared by hardware replacement.
  • Page 31: Warranty And Maintenance Options

    Product Information Guide T217 WARRANTY AND MAINTENANCE OPTIONS Maintenance options include on-premises service with business-day and 24-hour choices, with depot service as a secondary choice. Maintenance contracts cover the entire system, not just parts of it. During the ONE-YEAR warranty period or the term plan, business-day coverage is included in the purchase or term plan price, and 24-hour coverage, on-premises service is offered as an option.

This manual is also suitable for:

Spirit 616

Table of Contents