Fluke ProcessMeter 787 User Manual page 41

Processmeter
Hide thumbs Also See for ProcessMeter 787:
Table of Contents

Advertisement

DC Millivolts Measurement
Range (mV dc)
400.0
AC Volts Measurement
Range (ac)
400.0 mV
4.000V
40.00V
400.0V
1000V
Specifications are valid from 5% to 100% of amplitude range.
AC conversion: true rms
Maximum crest factor: 3
For non-sinusoidal waveforms, add (2% reading + 2% f.s.) typical
Input impedance: 10 M (nominal), < 100 pF, ac-coupled
Common mode rejection ratio: >60 dB at dc, 50 Hz, or 60 Hz
Resolution
0. 1 mV
Resolution
50 Hz to 60 Hz
0.1 mV
0.001V
0.01V
0.1V
1V
Accuracy (% of Reading + Counts)
0.1% + 1
Accuracy, (% of Reading + Counts)
45 Hz to 200 Hz
0.7% + 4
1.2% + 4
0.7% + 2
1.2% + 4
0.7% + 2
1.2% + 4
0.7% + 2
1.2% + 4
0.7% + 2
1.2% + 4
ProcessMeter
Specifications
200 Hz to 500 Hz
7.0% + 4
7.0% + 4
7.0% + 4
7.0% + 4
7.0% + 4
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents