Download Print this page

Ferroli Falcon Installation, Servicing And User Instructions Manual page 6

Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control installation, servicing and user instructions

Advertisement

Heat output
MODEL
kW
FALCON
23,3
MODEL
1
Ø
FALCON
3/4"
1/2"
Main injectors (mm)
MODEL
G20 - NG G31 - LPG
Ø
FALCON
12x1,30
Gas supply pressures
MODEL
G20 - NG
mbar
FALCON
20
Domestic hot water
production with
MODEL
t 30°C
l/min.
FALCON
11,1
Heat
input
kW
kW
9,7
25,8
Connections
2
3
4
5
Ø
Ø
Ø
Ø
1/2"
1/2"
3/4"
Gas flow rates to main burners
G20 - NG
Ø
m
3
/h
12x0,77
2,73
Gas pressure at main burner for central heating
G31 - LPG
minimum
mbar
mbar
37
2,5
Domestic hot water
production with
t 35°C
l/min.
9,5
Domestic hot
water heat
input
kW
kW
11,5
23,3
Expansion vessel
Pre-pressurising
Capacity
value
Litres
bar
7
1
for central heating
G31 - LPG
kg/h
2,00
G20 - NG
nominal
minimum
mbar
mbar
11,8
7,8
Max. working pressure
domestic hot water
G20 - NG G31 - LPG
mbar
mbar
11,8
36,0
Domestic hot
Boiler water
water circuit
contents
contents
Litres
Litres
1,5
Max. working
Max. working
pressure
pressure hot
central heating
water circuit
circuit
bar
3
Gas valve
Ø 1/2"
H. V K4105G
Safety valve
G31 - LPG
nominal
mbar
36,0
Protection
level
IP44
0,8
bar
6
bar
3
Weight
kg
38