Konica Minolta bizhub 501/421/361
Specification & Installation Guide
Space Requirements
(continued)
64.5
(1637)
56.1
(1425)
49
(1245)
3.9
(100)
19.2
(487)
64.5
(1637)
45.3
37.1
(1150)
(943)
Environmental Requirements
Temperature
Humidity
Noise while engine under operation
Ozone emission
Fusing range
27
23.2
24.3
(685)
(590)
(618)
15.6
(397)
16.5
418
(418)
78.5
(1993)
bizhub 501/421/361 + PC-206 + FS-522 + MT-501 + LU-203
27
35.8
(910)
(685)
26.8
(680)
15.6
(397)
93.9
(2385)
bizhub 501/421/361 + PC-407 + FS-523 + LU-203
50° to 86° F
10–80% RH
501: < 75 dB
421: < 73.7 dB
361: < 71.6 dB
< 1.5 mg/h
165C–190C
3.9
(100)
6.9
(176.4)
21.7
(550)
61.5
(1561.4)
3.9
6.95
(100)
(176.4)
23.2
21.7
(550)
(590)
61.5
(1561.4)
Electrical Requirements
Line options:
Dedicated
(Recommended)
Voltage:
120 V AC
Amperage:
12 A
Cycles:
60 Hz
NEMA Part No.: 5–15R
Cord Length:
8 ft. 2 in.
Unit: Inch(mm)
7.8
(200)
25
(635)
Unit: Inch(mm)
7.8
(200)
25
(635)
NEMA Diagram for 5-15R