Sas Drive In A Romb Raid 5 May Drop Offline During A Reboot In The Intel® Server System Sr2500Pallx; Intel® Server System Sr2500Allx Sixth Hard Drive Filler Panel Is Difficult To; Remove - Intel BB5000XALR Specification

Specification update
Table of Contents

Advertisement

Monthly Specification Update
Workaround
If the module is not reset, you can force it to reset by removing and replacing
AC power to the system.
39.
SAS drive in a ROMB RAID 5 may drop offline during a reboot in the
Intel® Server System SR2500PALLX
Problem
When five or six drives are inserted and SAS ROMB RAID 5 is configured,
drives may drop offline during a system reboot in the Intel
SR2500PALLX.
Implication
This only happens with specific drives. Updating the drive's firmware to the
latest version should resolve this issue.
Status
This erratum is fixed by updating SAS drive firmware.
Workaround
None.
40.
Intel® Server System SR2500ALLX sixth hard drive filler panel is difficult
to remove
Problem
It may be difficult to remove the Intel
drive filler panel.
Implication
Certain systems may exhibit this issue. Root cause was found with the
manufacturing tooling.
Status
No fix.
Workaround
Customers who order ASR2500SIXDRV with MM#885929 (TA# D43807-004)
will also get a installation guide.
Enterprise Platforms and Services Marketing
®
Server System SR2500ALLX 6
®
Server System
th
hard
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

S5000palS5000xalSr1500alSr1550alSr2500al

Table of Contents