Lenovo 7269D7U - Topseller M58e Sff E7500 2.93G 3Gb 320Gb Dvdrw W7p/Xpp Hardware Maintenance Manual page 62

Hardware maintenance manual
Hide thumbs Also See for 7269D7U - Topseller M58e Sff E7500 2.93G 3Gb 320Gb Dvdrw W7p/Xpp:
Table of Contents

Advertisement

Diagnostic Error Code
035-198-XXX RAID interface test aborted
035-199-XXX RAID interface test failed, cause unknown
071-000-XXX Audio port Interface Test Passed
071-00X-XXX 071-01X-XXX 071-02X-XXXAudio port
error
071-03X-XXX Audio port failure
071-04X-XXX Audio port failure
071-195-XXX Audio port Test aborted by user
071-196-XXX Audio port test halt, error threshold
exceeded
071-197-XXX Audio port test warning
071-198-XXX Audio port test aborted
071-199-XXX Audio port test failed, cause unknown
56
ThinkCentre Hardware Maintenance Manual
FRU/Action
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 521
3. Go to "Undetermined problems" on page 65
1. See "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 521
3. Replace component under function test
No action
1. Run Setup
2. Flash the system. See "Flash update procedures"
on page 521
3. System board
1. Speakers
2. Microphone
3. Audio card, if installed
4. System board
1. Run Setup
2. Audio card, if installed
3. System board
Information only Restart the test, if necessary
1. Press F3 to review the log file
2. Restart the test to reset the log file
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 521
3. Go to "Undetermined problems" on page 65
1. See "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 521
3. Replace component under function test

Hide quick links: