Lenovo 7269D7U - Topseller M58e Sff E7500 2.93G 3Gb 320Gb Dvdrw W7p/Xpp Hardware Maintenance Manual page 61

Hardware maintenance manual
Hide thumbs Also See for 7269D7U - Topseller M58e Sff E7500 2.93G 3Gb 320Gb Dvdrw W7p/Xpp:
Table of Contents

Advertisement

Diagnostic Error Code
030-03X-XXX 030-04X-XXX SCSI interface error
030-195-XXX SCSI interface Test aborted by user
030-196-XXX SCSI interface test halt, error threshold
exceeded
030-197-XXX SCSI interface test warning
030-198-XXX SCSI interface test aborted
030-199-XXX SCSI interface test failed, cause unknown
035-000-XXX RAID interface Test Passed
035-0XX-XXX RAID interface Failure
035-195-XXX RAID interface Test aborted by user
035-196-XXX RAID interface test halt, error threshold
exceeded
035-197-XXX RAID interface test warning
FRU/Action
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
Information only Restart the test, if necessary
1. Press F3 to review the log file
2. Restart the test to reset the log file
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 521
3. Go to "Undetermined problems" on page 65
1. Go to "Undetermined problems" on page 65
2. Flash the system and re-test. See "Flash update
procedures" on page 521
3. Replace component under function test
No action
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
Information only Restart the test, if necessary
1. Press F3 to review the log file
2. Restart the test to reset the log file
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
Chapter 7
.
Symptom-to-FRU Index
55

Hide quick links:

Advertisement

Table of Contents
loading