Installing The Air Hoses - Brother RH-9800 Instruction Manual

Electronic eyelet button holer
Hide thumbs Also See for RH-9800:
Table of Contents

Advertisement

3. INSTALLATION

3-11. Installing the air hoses

Connect the air hose from the compressor to the air unit underneath the work table.
(3)
(2)
0834Q
Adjusting the air pressure
Set the air pressure for the knife pressure adjustment regulator (3) to the lowest pressure at which the knife can still cut
the material. Set the standard air pressure for the main regulator (1) to 0.5 MPa.
To increase the air pressure
(2)
To decrease the air pressure
(2)
To close
(5)
To loosen
10
Closed
(1)
(4)
(3)
(0.3 MPa)
(1)
(0.5 MPa)
(4)
(3)
(1)
(0.3 MPa)
(0.5 MPa)
(6)
To tighten
1. Turn the nut (1) at the end of the air hose, and then
connect the hose to the valve (2).
2. Open the air cock (3) on the compressor.
Check that there is no air leaking from the valve
connection.
3. Open the cock (3) by turning it in the direction of the
Open
arrow.
The meter needle will move clockwise.
4. Adjust the air pressure by following the procedure on
the next page.
(3)
0835Q
1. Gently lift the knob (2) of the main regulator (1) and
turn it in the direction of the arrow in the illustration.
The pressure will increase when the knob (2) is turned
clockwise.
2. Gently lift the knob (4) of the knife pressure adjustment
regulator (3) and turn it in the direction of the arrow in
the illustration.
The pressure will increase when the knob (4) is turned
clockwise.
* The pressure for the knife pressure adjustment
regulator (3) is adjusted to 0.3 MPa. Be careful not
to
increase this pressure needlessly, otherwise
poor cutting performance or damage to the knife
0836Q
may result.
1. Close the cock (5). (The needle will remain at the high
pressure position.)
2. Turn the knob screw (6) in the direction of the arrow in
the illustration to loosen it. Make sure that you turn it in
the correct direction.
The air will escape from the reservoir and the needle
will drop.
3. Tighten the knob screw (6).
4. To reduce the air pressure, gently lift knob (2) or knob
(4) and turn it counterclockwise.
5. Open the cock (5). Air will enter the reservoir and the
needle will move
0837Q
RH-9800

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dh4-b980

Table of Contents