Power Management Module Error Codes - HP ProLiant DL985 Troubleshooting Manual

Hp proliant servers troubleshooting guide
Hide thumbs Also See for ProLiant DL985:
Table of Contents

Advertisement

For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP website
(http://www.hp.com/products/servers/proliant-bl/p-class/info).
Replace the interconnect module.
3.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP website
(http://www.hp.com/products/servers/proliant-bl/p-class/info).
Unknown server blade management module error code
LED code: 19-1
Location: Unknown
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
Press the server blade management module reset button.
1.
Replace the server blade management module.
2.

Power management module error codes

Power supply error codes
Location
Power Supply - Slot 1
Power Supply - Slot 2
Power Supply - Slot 3
Power Supply - Slot 4
Power Supply - Slot 5
Power Supply - Slot 6
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
Reseat the power supply.
1.
For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP website
(http://www.hp.com/products/servers/proliant-bl/p-class/info).
Reseat the power management module.
2.
Replace the power supply.
3.
Power management module board error codes
LED code: 7-1, 7-2, 7-3, 7-4, 7-5, 7-6, 7-7, 7-8, 7-9, 7-10, 7-11, 7-12, or 7-13
Location: Power management board
Action: Perform the following steps to resolve the problem. Stop when the problem is resolved.
Reseat the power management module.
1.
Replace the power management module.
2.
Power management module backplane error codes
LED code: 8-1, 8-2, 8-3, 8-4, 8-5, 8-6, 8-7, or 8-8
Location: Power management backplane
LED codes
1-1 or 1-2
2-1 or 2-2
3-1 or 3-2
4-1 or 4-2
5-1 or 5-2
6-1 or 6-2
Error messages 166

Advertisement

Table of Contents
loading

Table of Contents