Flexible connector hookup

Installer: Inform the consumer of the location of the gas shut-off valve.
If your area requires a rigid pipe
hookup, contact a qualified
installer, service agency, or gas
supplier.
The gas shut-off valve should
be installed in an accessible
location in the gas piping,
external to the appliance, for the
purpose of turning on or shutting
off the gas to the appliance.

Step 3. Convert to lp gas (optional)

All new gas ranges are shipped from the factory set up to use natural gas. Any
Samsung gas range can be converted to use LP gas. Refer to page 78 in the
User Manual to contact a qualified service technician.
The conversion process should only be performed by a qualified LP gas installer.
Conversion instructions and LP orifices will be supplied with the LP conversion
kit. The conversion to LP requires all burner orifices to be changed (5 surface
burners and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All
replaced orifices must be left with the consumer, including the instructions and
retrofit sizes and orifice indication.
BURNER ORIFICE SIZES AND
OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner
Location
RF¹
RF
2,3
LF¹
LF
2,3
RR
LR
CTR
BAKE
BROIL
¹ Model FX710BGS ² Model FX510BGS
3
Model NX583G0VBSR / NX583G0VBBB / NX583G0VBWW
30_ installation instructions
(Install)FX710BGS_FX510BGS_DG68-00357A-01_EN_120706.indd 30
Orifice Size
BTU Rate
[mm]
14,500
1.05/0.52
12,500
1.06
11,500
1.04
10,000
0.98
4,000
0.62
7,500
0.83
7,500
0.83
15,000
1.15
11,500
1.02
Gas Shut-Off Valve
0.5-in or 0.75-in Gas Pipe
Adapter
Flex Connector
(6-ft max.)
Adapter
BURNER ORIFICE SIZES AND
OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner
BTU Rate
Location
RF¹
18,000
RF
17,000
2
RF
17,000
3
LF
15,000
1,2
LF
12,000
3
RR
5,000
1,2
RR
5,000
3
LR
9,500
CTR
9,500
BAKE
18,000
BROIL
13,500
Tubing Line to
Oven Burner
Control Valve
Tubing Line
to Cooktop
Control
Manifold
Pressure
Regulator
Orifice Size
[mm]
1.80/0.73
1.90
1.92
1.78
1.60
1.00
1.01
1.40
1.38
1.90
1.64
2012-07-09