Shutdown Procedure - Compaq StorageWorks 3000 - RAID Array Release Note

Raid array for microsoft windows
Hide thumbs Also See for StorageWorks 3000 - RAID Array:
Table of Contents

Advertisement

Removing Disk Partitions
1.
From the Disk Administrator, click the partition you wish to delete.
2.
Access the Partition menu and choose Delete.
3.
Continue selecting and deleting the partitions until you have deleted all the partitions
you wish. When finished, click Commit Changes Now. You may now reconfigure
the StorageWorks RAID Array 3000 Storage Subsystem Array using Command
Console Client.
4.
Reboot your system so Windows NT will recognize the changes.

Shutdown Procedure

You must issue shutdown from SWCC. Do not turn off the system power before
shutdown is issued. (When shutdown is issued from SWCC, the controller first flushes
the cache to the disk drive, then stops blinking).
I
If a controller requires a rebind, the SCSI bus must be quiesced before performing
this operation. All I/O must be stopped before replacing the failed controller.
I
Reconnecting the SWCC client may be necessary if any of the following conditions
occur:
1.
Controller failover.
2.
Lost connection to the subsystem.
3.
SWCC does not reflect the correct state of the controllers after a FAILBACK
(rebind).
4.
Deletion of virtual disks and/or RAIDsets.