McDATA StorageWorks 2/140 - Director Switch Planning Manual page 301

Products in a san environment
Hide thumbs Also See for StorageWorks 2/140 - Director Switch:
Table of Contents

Advertisement

E/OSc versus E/OSn and E/OSi - Management-Related Differences (Continued)
Table B-3
Feature
Special port states and
Port state Inactive with special
reason codes
reason codes Reserved and
InvalidOTPConfig not
supported.
Inactive zone set
Only the active zone set is
support
stored.
Maintenance mode
Maintenance mode commands
command set
supported through the product
serial maintenance port
(protected access), but
command set differs from the
Intrepid 10000 Director.
Diagnostics
Diagnostics supported for one
(port granularity)
port or all ports on FPM, UPM, or
XPM cards.
E/OSc 8.0
Logical port addresses FE and
FF forced offline and placed in
special state Inactive with
reason code Reserved if FICON
CUP is enabled. FICON states
are Internal Port (address FE)
and Unimplemented (address
FF).
If the top or bottom optical
paddle pairs in a line module are
both 10.2000 Gbps paddles,
then ports in one paddle are set
offline and placed in the Inactive
state with special reason code
InvalidOTPConfig. If the
director powers up with two
10.2000 Gbps paddles in a pair,
the upper paddle is set offline. If
a second 10.2000 Gbps paddle
is added to an operating director,
the newly-inserted paddle is set
offline.
Up to 32 inactive zone sets
saved and supported through
the CLI interface.
Maintenance mode commands
supported through the product
serial maintenance port
(protected access). Maintenance
mode entered as a special user
through the CLI interface. All CLI
commands available in
maintenance mode.
Diagnostics supported for one
port or all ports on an optical
paddle pair. User provides a data
pattern and duration through the
CLI interface.
E/OSn 6.0
At the CLI, port state Testing
indicates a Fibre Channel port is
enabled without a device
attached.
At the CLI and Element Manager
application, port state Needs
Reboot indicates SAN Router
requires a reboot because a
Fibre Channel port is configured
as a GbE port (or vice versa).
Only the active zone set is
automatically stored. Selected
inactive zone sets saved and
supported through the
SANvergence Manager
application.
Maintenance mode commands
supported through the product
serial maintenance port
(protected access) or Telnet
connection.
Diagnostics supported for one
port or all ports when the SAN
router is offline.
Firmware Summary
Firmware Summary
E/OSi 4.6
B-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents