System Error Messages

HLO_System Error Messages

HLO is a part of the Fabric Shortest Path First (FSPF) protocol that handles the
HELLO protocol between adjacent switches. The HELLO protocol establishes
connectivity with a neighbor switch, establishes the identity of the neighbor
switch, and exchanges FSPF parameters and capabilities.

HLO-DEADTIMEOUT

Message
<switch number> Error HLO-DEADTIMEOUT, 2, Incompatible Inactivity timeout
<dead timeout> from port <port number>, correct value <value>
Explanation
The HELLO message was incompatible. The dead timeout value does not match
the value specified in the FSPF protocol. Since the dead timeout value is
incompatible, the local switch will not accept FSPF frames from the remote
switch.
Recommended Action
The dead timeout value of the remote switch must be made compatible with the
value specified in the FSPF protocol. See the manufacturer's documentation to
change this value.
Severity
Error