PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications

7.8 Temp Read Command

Command
"CR6" [CR]
Get the information of temperature inside a projector.
Detail
With several built-in temperature sensors, it can get all the temperatures at once.
Acceptable
%1
Response
%2
%3
Unacceptable

7.9 Lamp Mode Read Command

Command
"CR7" [CR]
Get lamp mode.
Detail
In the projector with single lamp, get ON/OFF status of the lamp
Acceptable
%1
Response
Unacceptable
"%1 _ %2 _ %3" [CR]
%1 = Temp. of sensor 1
%2 = Temp. of sensor 2
%3 = Temp. of sensor 3
Temperature data basic format is "_00.0". ("_" indicates a space)
When the temperature goes under 0, it starts with "-" instead of a
space like "-05.5" [CR].
When no temperature data returns due to hardware problems, it
starts with "E" like"E00.0" [CR].
With several built-in temperature sensors, the projector returns
the values in succession.
"_31.5_ _35.2_ 33.4 " [CR]
The first sensor's data is followed by one space and afterwards
the second sensor's data.
"?" [CR]
"%1" [CR]
"00" [CR] = Lamp is ON.
"01" [CR] = Lamp is OFF.
"?" [CR]