PLC-ZM5000/ZM5000L Basic Serial Command Functional Specifications
6.10 INPUT 3 Command
Command
"C07" [CR]
Select Input 3. This command works differently from the command by "Input 3"
key of the remote control. When Input 3 has been selected, this command does
Detail
not execute the source switching; just for switching to Input 3.
Although projector returns "OK", Input search is not executed with this command
while Input button is set to Mode2 or Mode3.
Acceptable
Response
Unacceptable
6.11 NETWORK Command
Command
"C08" [CR]
Select Network Input.
Detail
Although projector returns "OK", Input search is not executed with this command
while Input button is set to Mode2 or Mode3.
Acceptable
Response
Unacceptable
6.12 VOLUME + Command
Command
"C09" [CR]
Volume Up.
Detail
This command works the same way as "VOLUME +" button of the remote control.
Acceptable
Response
Unacceptable
6.13 VOLUME – Command
Command
"C0A" [CR]
Volume Down.
Detail
This command works the same way as "VOLUME -" button of the remote control.
Acceptable
Response
Unacceptable
6.14 SOUND MUTE ON Command
Command
"C0B" [CR]
Sound Mute On.
Detail
This command works the same way as "MUTE" button of the remote control for
Sound Mute On, but does not work for Sound Mute Off.
Acceptable
Response
Unacceptable
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
13/28