Chapter 4
To install a VRM in an HP NetServer LPr:
1. Orient the VRM as shown in Figure 4-6. The component side of the VRM
faces the center of the system board. Do not touch the components on the
VRM.
Secondary
Processor
Module
Secondary
Processor
Position
Figure 4-6. Installing a VRM in an HP NetServer LPr
2. Gently press the VRM down into the socket until it is seated completely.
CAUTION
When installing the VRM, push only on the edge of the main
VRM board. Do not push on the large flat surface (if your
VRM model has one) or any components on the board.
Pushing on any part of the VRM except the edge of the main
board may result in damage to the VRM. Damage caused by
improper installation is not covered by any HP warranty.
3. Verify that the VRM is installed completely in the socket. When the VRM
is installed completely, the release latches at the ends of the socket will be
closed.
44
Installation in E 60 and LPr
Do Not Touch VRM
Components
Secondary VRM Slot
VRM