Chapter 3
2. Holding the VRM as shown in Figure 3-14, press it firmly into the VRM
socket on the processor board. Be sure to press only on the thin edge of the
main VRM board when inserting the VRM into the socket.
Main VRM
Board
VRM Release Latches
(shown in open position)
Figure 3-14. Installing a VRM in HP NetServer LC 3 and LH 3/3r
CAUTION
When installing the VRM, push only on the edge of the main
VRM board (see Figure 3-14). Do not push on the large flat
surface (if your VRM model has one) or any components on
the board. Pushing on any part of the VRM except the edge of
the main board may result in damage to the VRM. Damage
caused by improper installation is not covered by any HP
warranty.
3. Verify that the VRM is installed completely in the socket. When the VRM
is installed completely, the release latches (see Figure 3-14) at the ends of
the socket will be closed.
Installation in LC 3 and LH 3/3r
Caution:
Do not push here
VRM Socket
29