Command-Line Examples - HP Rx2620-2 - Integrity - 0 MB RAM User Manual

Integrity servers with microsoft windows server 2003 for itanium-based systems
Hide thumbs Also See for Rx2620-2 - Integrity - 0 MB RAM:
Table of Contents

Advertisement

/target "netAddress"
/logdir "path"

Command-line examples

Although lowercase letters are used in the following examples, the ISP command line interface
is not case-sensitive. You can use either uppercase or lowercase letters. However, the operating
system environment variable is case-sensitive. (For example, %I is not the same as %i).
Example 1
The following command line input deploys the latest ISP components:
hpsum /use_latest /allow_non_bundle_components /silent
All software components from the ISP components that HP Smart Update Manager determined
needed to be installed are installed.
Example 2
The following command line input deploys the previous version of the ISP only and forces all
the components to be installed:
hpsum /f BP000315.xml
or
hpsum /b BP000315.xml /f
All software components from the ISP that HP Smart Update Manager determined needed to
be installed are installed.
Example 3
The following command line input deploys two software components:
hpsum /f cp008097.exe cp008257.exe
or
hpsum cp008097.exe cp008257.exe /f
The two components are installed. No other software is installed.
Example 4
The following command line input deploys the latest ISP and later versions of components in
the bundle to three remote hosts and forces all components to be installed:
hpsum /group "Management Servers" /current_credential /use_latest /allow_update_to_bundle
/allow_non_bundle_components /f /override_existing_connection /continue_on_error ServerNotFound /silent /logdir
"Management_Server_Files"
or
hpsum /target "Management Server1" /target "Management Server2" /target "Management Server3" /user administrator
/password letmein /use_latest /allow_update_to_bundle /allow_non_bundle_components /f
/override_existing_connection /continue_on_error ServerNotFound /silent /logdir "Management_Server_Files"
All the firmware components, software components from the ISP, cp008097.exe, and cp008257.exe
are installed on Management Server1, Management Server2, and Management Server3.
34
Advanced installation of ISPs in Windows
Specifies the IP address or the DNS name of a HP
BladeSystem c-Class Onboard Administrator or remote
host. When two Onboard Administrators are in an
enclosure, this argument must be the active Onboard
Administrator.
Enables you to redirect the output from HP Smart Update
Manager or the HP BladeSystem c-Class Onboard
Administrator flash utility to a different directory than the
default location. For Windows® components, the default
location is
%SYSTEMDRIVE%\CPQSYSTEM\hp\lognetAddress and
the redirected location is path\hp\log\netAddress.