18. Ensure that the ten screw holes in the new system board are aligned with the corresponding mounting
studs on the chassis. Then, install the ten screws following the numerical sequence as shown to
secure the new system board on the chassis.
Figure 103. Installing the screws to secure the system board
19. Remove the microprocessors from the old system board and install them directly on the new system
board. See "Installing or replacing the microprocessor" on page 113.
20. Install the heat sinks that are removed from the old system board on the new system board. See
"Installing or replacing a heat sink" on page 110.
21. The old system board must be returned with the microprocessor socket covers to protect the pins on
the microprocessor sockets during shipping and handling. Use the microprocessor socket covers
removed from the new system board.
To install a microprocessor socket cover on the old system board, do the following:
a. Ensure that the small handle and the microprocessor retainer are in the fully open position. See
"Installing the second microprocessor" on page 113.
Note: Do not drop anything onto the microprocessor socket while it is exposed.
.
Chapter 6
Installing, removing, or replacing hardware
151