CAUTION: If you plan to use an external antenna for the 802.11b/g or 802.11a radio, install the
antenna at least 20 cm from the access point.
Suspended Ceiling Installation — Drop Ceiling Tiles
This procedure applies to T-bars that are 23.9 mm (15/16 inches), 14.2 mm (9/16 inches), or 15.9 mm
(5/8 inches) wide. You can also use this procedure for flush ceilings with 14.2-mm (9/16-inch) or 15.9-
mm (5/8-inch) T-bars.
Mobility
AP3750 access point
point
Use the mounting template to cut a hole for the Category 5 cable.
1
Install the T-bar clamp that fits the T-bar.
2
T-bar
23.9-mm (15/16-in) or 14.2-mm (9/16-in) T-bar
(The clamps are different widths but the assembly is the same.)
T-bar
Mounting
Mounting template
template
T-bar clamp halves
T-bar clamp halves
15.9-mm (5/8-in) T-bar
T-bar clamps
T-bar clamps
(use set that fits T-bar)
(use set that fits T-bar)
Slide together
Slide together
8
Mounting
Mounting
bracket
bracket