Access
Read-write
Status
Mandatory
Return value
The switch log level setting. See
Table 8
connUnitEventFilter read return values
Security levels
Critical
Warn
Info
None
Table 9
onnUnitEventFilter control write values
Control value
Emergency (2)
Alert (3)
Critical (4)
Error (5)
Warning (6)
Notify (7)
Info (8)
Debug (9)
Mark (10)
Unknown (1)
connUnitNumEvents (1.3.6.1.3.94.1.6.1.26)
Number of events currently in the connUnitEventTable
Syntax
INTEGER
Access
Read-only
Status
Mandatory
Return value
An integer indicating the number of events in the connUnitEventTable
connUnitMaxEvents (1.3.6.1.3.94.1.6.1.27)
Maximum number of events that can be defined in connUnitEventTable
Syntax
HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Simple Network Management Protocol Reference Guide
Table 8
and
Table 9
Return value
Critical(4)
Warning(6)
Info(8)
Unknown(1)
Result
Critical
Critical
Critical
Warn
Warn
Info
Info
Info
Info
None
for connUnitEvent-Filter values.
79