Table 30
lists the trap information returned for the connUnitEventDescr variable.
Table 30
Filter trap levels
Trap type
connUnitPortStatusChange
connUnitDeletedTrap
connUnitStatusChange
connUnitSensorStatusChange
connUnitEventTrap
connUnitSensorStatusChange (1.3.6.1.3.94.0.5)
The overall status of the connectivity unit has changed. The recommended severity level (for filtering) is
alert. Sent whenever any of the following notifications occur:
Chassis.PsBadAlarm
Chassis.PsOkAlarm
Chassis.FanBadAlarm
Chassis.FanOkAlarm
Blade.OverheatAlarm
Blade.OverwarmAlarm
Variables:
{ connUnitSensorStatus }
138 Fibre Alliance MIB Objects
Cause
User port config change
User port state change
E_Port alarm
Fabric change and unit deleted
Switch state change
Switch reset
Power supply bad alarm
Power supply OK alarm
Fan bad alarm
Fan OK alarm
Overheat alarm
Overwarm alarm
Temperature OK alarm
SNMP config change
Switch config change
System config change
Topology change
Zoning change
Zoning merge failure
NameServer change
Generic alarm
Generic event
Filter level
eventSeverity_info
eventSeverity_info
eventSeverity_critical
eventSeverity_info
eventSeverity_info
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_info
eventSeverity_info
eventSeverity_info
eventSeverity_info
eventSeverity_info
eventSeverity_critical
eventSeverity_info
eventSeverity_critical
eventSeverity_warning