PLC_ET30L Basic Serial Command Functional Specifications

6.59 PRESENTATION TIMER Command

Command
"C8A" [CR]
Start Timer for presentation
This command works the same way as "P-TIMER" button of the
Detail
remote control.
Acceptable
Response
Unacceptable
6.60 KEYSTONE ↑ Command
Command
"C8E" [CR]
Correct keystone distortion by reducing upper part of image. This command
Detail
invokes both operations of keystone distortion correction and OSD display,
regardless of whether the "KEYSTONE" OSD has been already displayed or not.
Acceptable
Response
Unacceptable
6.61 KEYSTONE ↓ Command
Command
"C8F" [CR]
Correct keystone distortion by reducing lower part of image.
Detail
invokes both operations of keystone distortion correction and OSD display,
regardless of whether the "KEYSTONE" OSD has been already displayed or not.
Acceptable
Response
Unacceptable
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]