Chapter 30
Configuring and Managing Zones
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Expand a VSAN and select a zone set in the Logical Domains pane.
Step 1
You see the zone set configuration in the Information pane. The Active Zones tab is the default.
Click the Policies tab.
Step 2
You see the configured policies for the zone (see
Figure 30-27
Step 3
In the Propagation column, choose fullZoneset from the drop-down menu.
Step 4
Click Apply Changes to propagate the full zone set.

Enabling a One-Time Distribution

You can perform a one-time distribution of inactive, unmodified zone sets throughout the fabric. To
propagate a one-time distribution of the full zone set using Fabric Manager, follow these steps:
Choose Zone > Edit Local Full Zone Database.
Step 1
You see the Edit Local Full Zone Database dialog box.
Click the appropriate zone from the list in the left pane.
Step 2
Click Distribute to distribute the full zone set across the fabric.
Step 3
This procedure only distributes the full zone set information; it does not save the information to the
startup configuration. You must explicitly save the running configuration to the startup configuration
issue the to save the full zone set information to the startup configuration.
The one-time distribution of the full zone set is supported in interop 2 and interop 3 modes, not in
Note
interop 1 mode.
OL-17256-03, Cisco MDS NX-OS Release 4.x
Configured Policies for the Zone
Cisco MDS 9000 Family Fabric Manager Configuration Guide
Figure
30-27).
Zone Set Distribution