Temperature=Pressure
Relief Valve
Operation
The temperature-pressure
relief valve must be manually
operated
at least once a year.
* Burn hazard
, Hotwater discharge.
, Keep clear of relief valve
discharge outlet.
When checking
the temperature-pressure
relief valve operation,
make
sure that (1) no one is in front of or around
the outlet
of
the temperature-pressure
relief valve discharge
line, and (2) that
the water
discharge
will not cause
any property
damage,
as the
water
may be extremely
hot, see Figure 32.
TEMPERATURE-PRESSURE
RELIEF VALVE
DISCHARGE PIPE
FIGURE
32.
If after manually
operating
the valve,
it fails to completely
reset
and continues
to release
water, immediately
close the cold water
inlet to the water
heater,
follow
the draining
instructions,
and
replace
the temperature-pressure
relief valve with a new one.
If the temperature-pressure
relief valve on the appliance
weeps
or discharges
periodically,
this may be due to thermal
expansion.
You may have a check
valve installed
in the water
line or a water
meter
with
a check
valve.
Consult
the Sears
Service
Center
for
further
information.
Do not plug the temperature-pressure
relief valve.
Draining
• Burn hazard
• Hot water discharge.
• Keep hands clear of drain
valve discharge.
The water
heater
should
be drained
if being
shut down during
freezing
temperatures.
Also
periodic
draining
and cleaning
of
sediment
from the tank may be necessary.
1. Turn the gas control
knob to the "OFF"
position.
2. CLOSE
the cold water
inlet valve to the water
heater.
3.
4.
5.
OPEN a nearby
hot water faucet
and leave open
to allow for
draining.
Connect
a hose
to the drain
valve
and terminate
to an
adequate
drain.
OPEN
the
water
heater
drain
valve
to allow
for
tank
draining.
NOTE:
if the water
heater
is going
to be shut
down
and
drained
for an extended
period,
the drain
valve
should
be
left open
with
hose connected
allowing
water
to terminate
to an adequate
drain.
6. Close the drain
valve.
7. Follow the lighting
instructions
in the Lighting
section to restart
the water
heater.
Drain Valve Washer
Replacement
(See Figure 33)
1. Turn "OFF"
gas supply
to water
heater.
2. Follow
"Draining"
instructions.
3. Turning
counter
clockwise
( _
), remove
the cap.
4. Unscrew
the stem by turning
it counter
clockwise
(('%),
and
remove
it from the drain valve
body.
5. Remove
the bottom
washer
and put the new one in place.
6. Re-insert
the stem into the drain valve body and retighten
the
cap to the body using a wrench.
DO NOT OVER TIGHTEN.
7. Follow
instructions
in the Filling
The Water Heater
section.
8. Check for leaks.
9. Follow the lighting
instructions
in the Lighting
section to restart
the water
heater.
CAP
WASHER
STEM
FIGURE 33.
Service
Before
calling
for repair
service,
read the Start Up Conditions
and Operational
Conditions
found
in the Troubleshooting
Guide
of this manual.
If a condition
persists
or you are uncertain
about the operation
of
the water
heater,
let the Sears
Service
Center
check
it out.
Contact
Sears
Service
Center
at:
1-800-4-MY-HOME _¢ (1-800-469-4663).
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power miser 9153.330942153.330952

Table of Contents