Thiswaterheater s hallnotbe connected t o anyheating
systems orcomponent(s)
used with anon-potable
water heating
appliance.
Allpiping c omponents
connected tothisunit f orspace heating
applications
shall b esuitable f orusewithpotable water.
Toxic c hemicals, such asthose used forboiler treatment shall
notbeintroduced intothis system.
Water supply systems may, because ofsuch events a shigh line
pressure, frequent cut-offs ortheeffects ofwater h ammer, have
installed devices such aspressure reducing valves, check v alves,
back flowpreventers, etc. t ocontrol these types ofproblems.
When these devices arenotequipped withaninternal by-pass,
andnoother m easures aretaken, thedevices cause t hewater
system tobeclosed. A swater i sheated, itexpands (thermal
expansion) and closed s ystems donotallow fortheexpansion
ofheated w ater.
The water w ithin t hewater h eater tank expands asitisheated
and increases thepressure ofthewater system. Iftherelieving
point o fthewater h eater's t emperature-pressure
relief v alve
is reached, thevalve willrelieve theexcess p ressure. T he
temperature-pressure
relief valve
is not intended
for
the
constant
relief
of thermal
expansion.
This is an unacceptable
condition
and must
be corrected.
It is recommended
that any
devices
installed
which
could
create
a closed
system
have
a
by-pass
and/or the system
have an expansion
tank to relieve
the
pressure
built by thermal
expansion
in the water system.
Refer
to the Thermal
Expansion
section
under
Troubleshooting
Guide
or contact
local plumbing
authority
or local Sears
Service
Center
on how to control
this situation.
NOTE:
To protect
against
untimely
corrosion
of hot and cold
water
fittings,
it is strongly
recommended
that
di-electric
unions
or couplings
be installed
on this water
heater
when
connected
to copper
pipe.
Property
Damage
Hazard
• Avoid
water heater damage.
, Install thermal
expansion
tank if necessary.
- Do not apply heat to cold water inlet.
- Contact
qualified
installer
or Sears
Service
Center.
Look at the top of the water
heater.
The cold water
inlet is
marked
"COLD".
Put two or three turns
of Teflon tape around
the threaded
end of the threaded-to-sweat
coupling
and
around
both
ends
of the 314" NPT threaded
nipple.
Using
flexible
connectors,
connect
the cold water
pipe to the cold
water
inlet of the water
heater.
NOTE:
This water
heater
is super
insulated
to minimize
heat
loss
from
the tank.
Further
reduction
in heat
loss
can
be accomplished
by insulating
the
hot water
lines
from
the water
heater.
INSTALLATION
COMPLETED
USING
INSTALLATION
KIT
FLEXIBLE
WATER
SHUTOFF
CONNECTORS
VALVE
HOT WATER
_
COLD WATER
THREADED
TO
THREADED
TO
SWEAT COUPLIN
SWEAT COUPLING
3/4"THREADED_3/4"THREADED
COUPLING
COUPLING
DRAFT
HOOD
_"TEMPERATURE-
PRESSURE
RELIEF VALVE
_"-DISCHARGE
PIPE
(Do not cap or plug)
FIGURE
15,
6_
AIR
GAP
- FLOOR
DRAIN
T & P Valve
and Pipe insulation
Remove
insulation
for T & P valve
and pipe connections
from
carton.
Figure
15 shows
the typical
attachment
of the water
piping
to
the water
heater.
The water
heater
is equipped
with 3/4" NPT
water connections.
NOTE:
If using
copper
tubing,
solder
tubing
to an adapter
before
attaching
the
adapter
to
the
cold
water
inlet
connection.
Do not solder
the cold water
supply
line directly
to the cold water
inlet.
It will harm
the dip tube
and damage
the tank.
Look at the top cover
of the water
heater. The water outlet
is
marked
"HOT". Put two or three turns of Teflon tape around the
threaded
end of the threaded-to-sweat
coupling
and around
both
ends
of the 3/4"
NPT threaded
nipple.
Using
flexible
connectors,
connect
the hot water
pipe to the hot water outlet
on the water
heater.
TEFLON® is a registered trademark of E.I. Du Pont De Nemours and Company.
13
PiPE
iNSULATION
FLUE PiPE
FIGURE
15A.
Fit pipe insulation
over the incoming
cold water
line and the hot
water
line. Make sure that the insulation
is against
the top cover
of the heater.