Sediment Trap; Gas Piping - Kenmore 33094 - Power Miser 9 Owner's Manual

Ultra low nox gas water heater
Table of Contents

Advertisement

Breathing
Hazard o Carbon
Nono×id÷
Gas
, }lgh
att;_e
office
rn}o_stbe in, s talled fat
oper_or_
_ove
2,000 feet (610 m).
* Corltsct
a qualified
i_'stalle_ or serwoe
agelncy
Breathing carbo_ mese;< de can cause b_'as dama_}e or
death Always _ead arid ar_deF'stard r_st_uction m_r_uai
Water
heaters
covered
in this manual
have
been
tested
and
approved
for installation
at elevations
up to 2,000
feet (610
m) above
sea level.
For installation
above
2,000
feet (610
m),
the water
heater's
Btu input
should
be reduced
at the rate of
4 percent
for each
1,000
feet (305
m) above
sea
level which
requires
replacement
of the burner
orifice in accordance
with the
National
Fuel Gas Code ANSI
Z223.1/NFPA
54. Contact
your
local gas supplier
for further
information.
Failure
to replace
the standard
orifice
with
the proper
high
altitude
orifice
when
installed
at elevations
above
2,000
feet
(610 m) could
result in improper
and inefficient
operation
of the
appliance,
producing
carbon
monoxide
gas in excess
of the safe
limits. This could
result
in serious
injury or death.
Contact
your
local gas supplier
for any specific
changes
that may be required
in your area.
Sediment
Traps
Fire and Explosion
Hazard
- Contaminants
in gas
lines
can
cause fire or explosion.
• Clean
ail
gas
piping
before
installation.
- Install drip leg in accordance with
NFPA 54.
Contaminants
in the gas lines
may cause
improper
operation
of the gas control
valve
that
may
result
in fire or explosion.
Before
attaching
the gas line be sure that all gas pipe is clean
on the inside.
To trap
any dirt or foreign
material
in the gas
supply
line,
a drip
leg
(sometimes
called
a sediment
trap)
must
be incorporated
in the
piping.
The
drip
leg
must
be
readily
accessible.
Install
in accordance
with
the Gas Piping
section.
Refer
to the current
of the National
Fuel
Gas Code,
ANSI
Z223.1tNFPA
54.
A sediment
trap shall be installed
as close to the inlet of the water
heater
as practical
at the time of water
heater
installation.
The
sediment
trap shall be either
a tee fitting with a capped
nipple
in the bottom
outlet
or other device
recognized
as an effective
sediment
trap.
If a tee fitting
is used,
it shall
be installed
in
conformance
with one of the methods
of installation,
shown
in
Figures
19 and 20.
Fire and Explosion
Hazard
• Use
joint
compound
or tape
compatiblewith
propane.
Leak
teat
before
operating
heater.
-Disconnect
gas
piping
and
shut-off
valve
before
pressure
testing
system
GROUND
UNION JOINT!_
1
(OPTIONAL)
GAS CONTROL
VALVE
3" MIN.
I
DRIP LEG
(76.2 mm)
SEDIMENT TRAP)
Use pipe joint compound
or Teflon tape marked
as being resistant
to the action
of petroleum
(Propane
[L.P.]) gases.
The appliance
and its gas connection
must be leak tested before
placing
the appliance
in operation.
The
appliance
and
its
individual
shutoff
valve
shall
be
disconnected
from
the gas
supply
piping
system
during
any
pressure
testing
of that system
at test pressures
in excess
of
1/2 pound
per square
inch (3.5 kPa).
It shall
be isolated
from
the gas supply
piping
system
by closing
its individual
manual
shutoff valve during
any pressure
testing
of the gas supply
piping
system
at test pressures
equal
to or less than
1/2 pound
per
square
inch (3.5 kPa).
Connecting
the gas piping
to the gas control
valve of the water
heater can be accomplished
by either of the two methods
shown
in Figures
19 and 20.
®
TEFLON
is a registered trademark of E.I. Du Pont De Nemours and Company.
FIGURE
19, GAS PIPING WITH FLEXIBLE
CONNECTOR.
GROUND
(OPTIONAL)
UNION JOINT _!
_
BLACK
PIPE
GAS CONTROL
VALVE
3' MtN.
I
(76.2 mm)
SEDIMENT TRAP)
FIGURE 20. GAS PiPiNG WITH ALL
SLACK IRON PiPE TO GAS CONTROL.
17