WARNING!
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION:
To prevent damage to electrical components, properly ground the enclosure before beginning any
installation procedure. Improper grounding can cause ESD.

Installing the access panel

To install the access panel, reverse the removal procedure:
Slide the access panel into place on the chassis.
1.
Press down the access panel latch on top of the enclosure to secure the panel.
2.

Hard drive blank

CAUTION:
To prevent improper cooling and thermal damage, do not operate the enclosure unless all bays are
populated with either a component or a blank.

Removing the hard drive blank

Press in the release latches (1).
1.
Pull the hard drive blank out of the bay (2).
2.

Installing the hard drive blank

To install the blank, slide the blank into the bay until it locks into place.